AI-generated summary
In this retrospective study, the authors report on 920 teeth with dentinal hypersensitivity treated with 660 nm red photobiomodulation or with Nd:YAG (1064 nm) or Nd:YAP (1340 nm) lasers, tracked for one year using a pain scale. The authors report that all three approaches reduced pain, and that the red light group showed the largest reduction, with a mean score of zero at one year.
- Participants
- 920
- Who or what was studied
- Teeth with dentinal hypersensitivity (920 teeth in three treatment groups)
- Wavelengths
- 660, 1064, 1340 nm
- Limits stated in the abstract
- The study is retrospective and the abstract does not describe a control group or randomization.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
In this retrospective study, data for three different laser-assisted approaches for the management of dentinal hypersensitivity (DH) was collected (n = 920 teeth). In total, 387 teeth were treated with photobiomodulation (PBM) therapy with 660 nm red light laser (PBM group), 327 were treated with the Nd:YAG laser (1064 nm) and 206 were treated with the Nd:YAP laser (1340 nm). To assess the effectiveness of each treatment, a visual analogue scale (VAS) was used, where zero represented no pain at all and ten represented the greatest pain. VAS was used before (T0), immediately after (T1), one week after (T2), four weeks after (T3), six months after (T4) and one year after treatment (T5). Means and standard deviations of VAS at different follow-up times were calculated. Values were compared within and between groups. Statistical significance was considered to be achieved when p-value was less than 0.05. Confidence level was proposed to be 99% with a P value lower than 0.001. Within groups, a statistically significant reduction was obtained when the mean value of VAS at T0 was compared with T5. At T5, the PBM group had the highest reduction of VAS (with mean value of 0), while the Nd:YAG and Nd:YAP groups had scores of 1.065 ± 0.674 and 4.665 ± 0.674, respectively. Conclusion: this retrospective study showed that PBM therapy and irradiation with Nd:YAG and Nd:YAP lasers are effective in managing DH pain. However, PBM therapy was the only procedure that showed complete pain relief at six and twelve months after treatment.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 660 nm, 1064 nm, 1340 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Photobiomodulation, Visual analogue scale, Photobiomodulation therapy, Laser, Statistical significance. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.