AI-generated summary
The authors report an in vivo validation study of Monte Carlo modelling for extraoral photobiomodulation dosimetry, comparing simulated and measured light transmitted through the cheeks of four volunteers. They report good agreement, with mean measured transmission within 12% of the simulated values. The authors conclude that Monte Carlo modelling is a robust and reliable dosimetry method, though the study involved only four volunteers.
- Participants
- 4
- Who or what was studied
- Four study volunteers, with morphological data from MRI scans and in vivo cheek transmission measurements
- Limits stated in the abstract
- The validation was based on only four volunteers, and the optical properties used in the simulations were taken from the literature.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
An in vivo validation study was performed to confirm the accuracy of extraoral photobiomodulation therapy (PBMT) dosimetry determined by modelling. The Monte Carlo technique was utilized to calculate the fluence rate and absorbed power of light delivered through multi-layered tissue. Optical properties used during Monte Carlo simulations were taken from the literature. Morphological data of four study volunteers were acquired using magnetic resonance imaging (MRI) scans. Light emitting diode (LED) coupled to a power meter were utilized to measure transmitted power through each volunteer's cheek, in vivo. The transmitted power determined by Monte Carlo modelling was compared to the in vivo measurements to determine the accuracy of the simulations. Experimental and simulation results were in good agreement for all four subjects. The difference between the mean values of the measured transmission was within 12% from the respective transmission obtained using Monte Carlo simulations. The results of the study indicate that Monte Carlo modelling is a robust and reliable method for light dosimetry.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Dosimetry, Photobiomodulation, Photobiomodulation therapy, Light-emitting diode, Fluence. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.