KI-generierte Zusammenfassung
The authors compared a 980-nm diode laser, Gluma desensitizer, their combination, and a control for cervical dentin hypersensitivity in 20 patients. They report that the laser alone gave the lowest pain scores at one month, but no significant differences between groups were found at three months. The small sample and the short-term nature of the difference limit how far the findings can be generalized.
- Teilnehmende
- 20
- Wer oder was untersucht wurde
- 20 patients (5 men and 15 women) aged 25 to 60 years with cervical dentin hypersensitivity, 60 teeth in total
- Wellenlängen
- 980 nm
- Im Abstract genannte Einschränkungen
- The trial enrolled only 20 patients, and the reported group difference was significant at one month but not at three months.
Von einem KI-Modell allein aus dem Abstract dieser Arbeit verfasst und automatisch damit abgeglichen, kann aber trotzdem falsch sein. Kein medizinischer Rat. Lesen Sie die vollständige Arbeit. Siehe die redaktionellen Grundsätze.
Zusammenfassung (Abstract)
Objectives
In this study, we aimed to compare the effectiveness of Gluma and high-power 980-nm diode laser, alone or in combination, in the treatment of cervical dentin hypersensitivity.
Methods
A total of 20 patients (5 men and 15 women), aged 25 to 60 years, who met the inclusion criteria, were enrolled in this study. A total of 60 teeth were randomly divided into 4 groups: G1, 980 nm diode laser (in 2 sessions within a 1-week interval); G2, Gluma (in 2 sessions within a 1-week interval); G3, 980 nm diode laser plus Gluma; and G4: control. Thermal (cold spray) and air blast (air syringe of dental unit) stimuli were used to evaluate cervical dentin hypersensitivity in the patients. Their pain response was assessed using a visual analogue scale (VAS) before treatment (baseline), in the first treatment session (15 minutes after treatment), in the second treatment session (after 1 week), and in 2-week, 1-month, and 3-month follow-up sessions. The obtained data were analysed using non-parametric tests, including Kruskal-Wallis test, Friedman test, Mann-Whitney test, and Wilcoxon test, in SPSS Version 22 at a significance level of P < .05.
Results
Based on the results, there was a significant difference in the average VAS scores for cold and air blast stimuli between the 4 groups 1 month after the intervention (P < .05). Meanwhile, the laser group had the lowest VAS score for cold and air stimuli. On the contrary, no significant difference was found between the 4 groups 3 months after the intervention (P ˃ .05).
Conclusion
The present results showed that 980-nm diode laser alone was more effective than the other 2 intervention methods for 1 month.
Trial Registration
The study was registered in the Iranian Registry of Clinical Trials (IRCT20120901010703N5).
Abstract wiedergegeben unter der Lizenz CC BY. Quelle: PubMed, ein Dienst der National Library of Medicine.
Genannte Lichtparameter
Per Mustererkennung in Titel und Abstract gefunden. Die Angaben können unvollständig sein; prüfen Sie die Arbeit, bevor Sie Studien vergleichen.
- Wellenlänge
- 980 nm
Wie man eine klinische Studie liest: worauf Sie achten sollten, bevor Sie sich auf diese Art von Forschung verlassen.
Begriffe in dieser Arbeit: Laser, Visuelle Analogskala, Studienregistrierung. Jeder Begriff führt zu seiner Definition im Glossar.
Eine Zusammenfassung veröffentlichter Forschung, kein medizinischer Rat. Eine einzelne Studie klärt selten eine Frage. Siehe den Haftungsausschluss und wie man Forschung liest.