Gratis · 13,598 estudios indexados

lighttherapyresearch.com es un índice gratuito de investigación sobre fotobiomodulación y terapia de luz, reunida de las revistas científicas y los registros de ensayos de todo el mundo.

Secciones
Dispositivos y dosimetría

An investigation into the depth of penetration of low level laser therapy through the equine tendon in vivo

El uso de alcohol sin rasurado no se asoció con un aumento de la transmisión de la luz. Estos resultados sugieren que, al aplicar el láser sobre una estructura subcutánea en el caballo, la zona debe rasurarse y limpiarse previamente.

Extracto del resumen del artículo, traducido por un modelo de IA. Lee el artículo completo para ver los detalles.

Resumen generado por IA

Los autores midieron cuánta luz de un láser de bajo nivel de 810 nm atravesaba el tendón flexor superficial de diecisiete miembros anteriores de caballos in vivo. La transmisión de la luz no se vio afectada por el caballo individual, el color del pelaje ni la extremidad, pero fue mayor cuando la zona estaba rapada, con o sin limpieza con alcohol, que cuando no se había preparado. Los autores sugieren que la zona debe rasurarse y limpiarse antes de aplicar el láser sobre una estructura subcutánea en caballos.

Participantes
17
Quién o qué se estudió
Diecisiete miembros anteriores de caballos in vivo (caballos)
Longitudes de onda
810 nm
Límites indicados en el resumen
El resumen describe un pequeño estudio in vivo de tendones de miembros anteriores de caballos, por lo que los hallazgos podrían no ser transferibles a otros tejidos, especies o contextos de tratamiento.

Traducido por un modelo de IA a partir del resumen en inglés, que se escribió solo a partir del resumen de este artículo. Las cifras se comprobaron automáticamente con el resumen del artículo, pero el texto aun así puede ser incorrecto. No es consejo médico. Lee el artículo completo. Consulta la política editorial.

Resumen (abstract)

Low level laser therapy (LLLT) is frequently used in the treatment of wounds, soft tissue injury and in pain management. The exact penetration depth of LLLT in human tissue remains unspecified. Similar uncertainty regarding penetration depth arises in treating animals. This study was designed to test the hypothesis that transmission of LLLT in horses is increased by clipping the hair and/or by cleaning the area to be treated with alcohol, but is unaffected by coat colour. A LLLT probe (810 nm, 500 mW) was applied to the medial aspect of the superficial flexor tendon of seventeen equine forelimbs in vivo. A light sensor was applied to the lateral aspect, directly opposite the laser probe to measure the amount of light transmitted. Light transmission was not affected by individual horse, coat colour or leg. However, it was associated with leg condition (F = 4.42, p = 0.0032). Tendons clipped dry and clipped and cleaned with alcohol, were both associated with greater transmission of light than the unprepared state. Use of alcohol without clipping was not associated with an increase in light transmission. These results suggest that, when applying laser to a subcutaneous structure in the horse, the area should be clipped and cleaned beforehand.

Resumen reproducido bajo la licencia CC BY. Fuente: PubMed, un servicio de la National Library of Medicine.

Parámetros de luz mencionados

Detectados por patrones en el título y el resumen. Pueden estar incompletos, así que revisa el artículo antes de comparar estudios.

Longitud de onda
810 nm
Potencia
500 mW

Cómo leer un estudio individual: qué revisar antes de confiar en este tipo de investigación.

Términos de este artículo: Láser, Terapia láser de baja intensidad, Profundidad de penetración. Cada uno enlaza con su definición en el glosario.

Un resumen de investigación publicada, no consejo médico. Un solo estudio rara vez resuelve una pregunta. Consulta el aviso legal y cómo leer la investigación.

Estudios relacionados

Dispositivos y dosimetría

n-Value-Tuned Quasi-2D Perovskites for Wavelength-Selective Optoelectronic Synapses

Utilizando estas respuestas dependientes de la longitud de onda, la intensidad y la duración, construimos un modelo de regresión del historial de luz que relaciona la exposición acumulada con las advertencias eléctricas de peligro de luz azul y con los umbrales de fototoxicidad derivados de la literatura bajo distintas temperaturas de color.

Estudio · 12 de noviembre de 2026 · Li Y et al.