Gratis · 13,598 estudios indexados

lighttherapyresearch.com es un índice gratuito de investigación sobre fotobiomodulación y terapia de luz, reunida de las revistas científicas y los registros de ensayos de todo el mundo.

Secciones
Dolor y sistema musculoesquelético

Effects of endodontic retreatment by conventional therapy compared to combined therapy with an Er:YAG laser and photobiomodulation: A randomized clinical trial

La aplicación de láseres de diodo Er:YAG y de 635 nm mejoró la cicatrización de las lesiones periapicales (PL) y disminuyó el dolor postoperatorio.

Extracto del resumen del artículo, traducido por un modelo de IA. Lee el artículo completo para ver los detalles.

Resumen generado por IA

Los autores reportan un ensayo aleatorizado con 40 pacientes con lesiones periapicales crónicas asintomáticas en molares mandibulares, que compara el retratamiento de conductos convencional con la irrigación activada por láser Er:YAG y la fotobiomodulación de 635 nm. El tamaño de la lesión se midió mediante tomografía computarizada de haz cónico y el dolor mediante escala visual analógica. El grupo de prueba mostró un tamaño medio de lesión menor a los 6 meses y menos dolor postoperatorio.

Participantes
40
Quién o qué se estudió
Pacientes con lesiones periapicales crónicas asintomáticas en molares mandibulares tratados endodónticamente que fueron referidos para retratamiento de conductos radiculares
Longitudes de onda
635 nm
Límites indicados en el resumen
El resumen no describe limitaciones; reporta una muestra de un solo centro con 20 pacientes por grupo y resultados solo a los 6 y 12 meses.

Traducido por un modelo de IA a partir del resumen en inglés, que se escribió solo a partir del resumen de este artículo. Las cifras se comprobaron automáticamente con el resumen del artículo, pero el texto aun así puede ser incorrecto. No es consejo médico. Lee el artículo completo. Consulta la política editorial.

Resumen (abstract)

Background

The success of endodontic retreatment relies on the effective elimination of pathogenic microflora from the root canal.

Objectives

The study aimed to investigate the effects of an erbium-doped yttrium-aluminum-garnet (Er:YAG) laser and a 635-nm laser on the healing of asymptomatic chronic periapical lesions (PLs) in endodontically treated teeth and the reduction of postoperative pain.

Material And Methods

Forty patients with PLs in mandibular molars were referred for root canal retreatment (RCR). Conventional chemo-mechanical endodontic treatment was conducted in the control group (G1; n = 20). In the test group (G2; n = 20), in addition to conventional chemo-mechanical treatment, Er:YAG laser-activated irrigation (LAI) with 2% NaOCl and 17% EDTA was performed. The laser parameters were as follows: 50 mJ; 25 Hz; 1 W; 300 μs; a tip diameter of 300 μm; fluence of 71.4 J/cm2; and power density of 1,428.6 W/cm2. Subsequently, the canals were filled with thermo-condensed guttapercha, using the AH Plus sealer. In group G2, additional photobiomodulation (PBM) with a wavelength of 635 nm (400 mW, 5 s per point, a dose per point: 2 J, a dose per square centimeter: 4 J, an applicator diameter of 8 mm) was applied, with 2 application points at the apex level, administered over 4 sessions - on the treatment day, and after 24 h, 48 h and 96 h. Endodontic lesion remission was assessed by measuring the PL size with the use of cone-beam computed tomography (CBCT) at 6 and 12 months postoperatively. Postoperative pain was evaluated using the visual analog scale (VAS) after 1, 2 and 4 days.

Results

The study results demonstrated a statistically significant decrease in the mean PL size at 6 months postoperatively in the test group (mean PL size: 1.55 ±0.51 mm) as compared to the control group (mean PL size: 1.95 ±0.71 mm) (p < 0.05). In the test group, postoperative pain on VAS was significantly lower after the procedure (p < 0.05).

Conclusions

The application of Er:YAG and 635-nm diode lasers improved PL healing and decreased postoperative pain.

Resumen reproducido bajo la licencia CC BY. Fuente: PubMed, un servicio de la National Library of Medicine.

Parámetros de luz mencionados

Detectados por patrones en el título y el resumen. Pueden estar incompletos, así que revisa el artículo antes de comparar estudios.

Longitud de onda
635 nm
Densidad de energía (fluencia)
71.4 J/cm2
Potencia
1 W, 400 mW
Energía total
2 J, 4 J

Cómo leer un ensayo clínico: qué revisar antes de confiar en este tipo de investigación.

Términos de este artículo: Láser, Fotobiomodulación, Escala visual analógica, Grupo de control, Dosis, Longitud de onda, Fluencia. Cada uno enlaza con su definición en el glosario.

Un resumen de investigación publicada, no consejo médico. Un solo estudio rara vez resuelve una pregunta. Consulta el aviso legal y cómo leer la investigación.