Assessing the Safety and Efficacy of a Noninvasive Device in the Management of Musculoskeletal Pain Using Low-Level Light Therapy: Double-Blinded, Randomized, Placebo-Controlled, Multicentric Study

El dispositivo parece ser seguro y viable como complemento no farmacológico para el manejo del dolor musculoesquelético agudo y crónico.

Extracto del resumen del artículo, traducido por un modelo de IA. Lee el artículo completo para ver los detalles.

Resumen generado por IA

Los autores informan de un estudio doblemente ciego, aleatorizado y controlado con placebo en 240 adultos con dolor musculoesquelético agudo o crónico, que recibieron 30 minutos de tratamiento con un dispositivo LED de luz roja e infrarroja o con un dispositivo control de luz roja. El dolor autoinformado fue mayor en el grupo de tratamiento, con reducciones de hasta el 60 %, y no se informaron eventos adversos significativos. Los autores señalan que los hallazgos reflejan una respuesta analgésica a corto plazo y que se necesitan ensayos de mayor duración.

Participantes
240
Quién o qué se estudió
Adultos de 18 a 60 años con dolor musculoesquelético agudo o crónico
Límites indicados en el resumen
El resumen señala que los resultados deben interpretarse con cautela dada la metodología del estudio y el seguimiento a corto plazo, y que los hallazgos reflejan una respuesta analgésica a corto plazo y no una eficacia clínica definitiva.

Traducido por un modelo de IA a partir del resumen en inglés, que se escribió solo a partir del resumen de este artículo. Las cifras se comprobaron automáticamente con el resumen del artículo, pero el texto aun así puede ser incorrecto. No es consejo médico. Lee el artículo completo. Consulta la política editorial.

Resumen (abstract)

Background

Musculoskeletal pain significantly impacts quality of life and daily functioning. Light-based therapies, including those using red and infrared wavelengths, have shown potential in pain management due to their anti-inflammatory and tissue healing properties. CURAPOD, a pain management device developed by Litemed, uses a combination of visible red and infrared light for noninvasive pain relief.

Objective

This study aimed to assess the safety and efficacy of Litemed's pain management device (CURAPOD) in managing acute and chronic musculoskeletal pain at various pain sites, in comparison with a placebo, and to evaluate its efficacy across different skin types.

Methods

In a double-blinded, randomized, placebo-controlled, multicentric study, 240 participants (aged 18-60 years) with acute or chronic musculoskeletal pain were enrolled and treated with either the test or control device for 30 minutes. The test device contains 7 LEDs designed to emit a combination of visible red and infrared radiation, while the control device emits visible light of the red spectrum. Pain intensity was subjectively measured at baseline, at 30 minutes after treatment, and at time windows of 8 to 12 hours and 21 to 24 hours after treatment.

Results

A greater number of participants reported a reduction in pain (of up to 60%) in the treatment group than in the placebo group. Repeated measures ANOVA revealed significant effects of time (F3,684=282.37; P<.001) and treatment group (F1,228=662.12; P<.001), indicating that the relief experienced may be more sustained in the treatment group. No significant effects of pain site (F5,228=0.169; P=.97) or skin type (F5,228=0.8; P=.55) were observed, suggesting consistent action across anatomical locations and skin types. No significant adverse events were reported.

Conclusions

The device appears to be safe and viable as a nonpharmacological adjunct for managing acute and chronic musculoskeletal pain. Treatment with the device showed short-term pain reduction, with reports of up to 60% pain reduction within 30 minutes of use and sustained self-reported relief in pain for up to 20 hours after treatment. No significant effects of pain sites or skin type on reduction in visual analog scale scores were observed, suggesting broad applicability. However, these results must be interpreted with caution while considering the limitations inherent to the study methodology and short-term follow-up. These findings should be interpreted as evidence of short-term analgesic response rather than definitive clinical effectiveness. Further investigation through rigorously designed randomized controlled trials and longitudinal studies is necessary to definitively establish the efficacy of the device, the durability of its action, and the potential integration of CURAPOD into pain management strategies.

Resumen reproducido bajo la licencia CC BY. Fuente: PubMed, un servicio de la National Library of Medicine.

Cómo leer un estudio individual: qué comprobar antes de fiarte de este tipo de investigación.

Términos de este artículo: Controlado con placebo. Cada uno enlaza con su definición en el glosario.

Un resumen de investigación publicada, no consejo médico. Un solo estudio rara vez resuelve una cuestión. Consulta el aviso legal y cómo leer la investigación.

Estudios relacionados