In Vitro Mean Red Blood Cell Volume Change Induced by Diode Pump Solid State Low-Level Laser of 405 nm

Se sugirió que el LLL puede reducir el volumen de los glóbulos rojos, posiblemente debido al aumento de las concentraciones intracelulares libres de Ca(+2), que activan canales de K(+) dependientes de Ca(+2), con la consiguiente salida de iones K(+) y encogimiento celular.

Extracto del resumen del artículo, traducido por un modelo de IA. Lee el artículo completo para ver los detalles.

Resumen generado por IA

Los autores estudiaron el efecto de un láser de estado sólido bombeado por diodo de 405 nm y baja potencia sobre eritrocitos humanos en muestras de sangre mantenidas in vitro, con tiempos de exposición de 20 a 50 minutos. Informan que el volumen medio de los eritrocitos disminuyó significativamente, con el mayor efecto a los 40 minutos. Los autores sugieren un posible mecanismo que implica un aumento del calcio intracelular y una salida de potasio, pero se trató de un estudio in vitro.

Quién o qué se estudió
Eritrocitos humanos de muestras de sangre recogidas en tubos con EDTA (in vitro)
Longitudes de onda
405 nm
Límites indicados en el resumen
El estudio se realizó in vitro en muestras de sangre aisladas, por lo que los resultados pueden no reflejar los efectos en personas vivas.

Traducido por un modelo de IA a partir del resumen en inglés, que se escribió solo a partir del resumen de este artículo. Las cifras se comprobaron automáticamente con el resumen del artículo, pero el texto aun así puede ser incorrecto. No es consejo médico. Lee el artículo completo. Consulta la política editorial.

Resumen (abstract)

Objective

This study was conducted to investigate the effects of low-level laser (LLL) doses on human red blood cell volume. The effects of exposure to a diode pump solid state (DPSS) (λ = 405 nm) laser were observed.

Background Data

The response of human blood to LLL irradiation gives important information about the mechanism of interaction of laser light with living organisms. Materials and methods Blood samples were collected into ethylenediaminetetraacetic acid (EDTA)-containing tubes, and each sample was divided into two equal aliquots, one to serve as control and the other for irradiation. The aliquot was subjected to laser irradiation for 20, 30, 40, or 50 min at a fixed power density of 0.03 W/cm(2). Mean cell volume (MCV) and red blood cell (RBC) counts were measured immediately after irradiation using a computerized hemtoanalyzer.

Results

Significant decrease in RBC volume (p < 0.05, p < 0.0001, p < 0.0001, and p < 0.05, respectively) was induced with variation in laser doses. The highest response was observed with an exposure time of 40 min. This result was reproduced in RBCs suspended in a buffered NaCl solution. In contrast to this finding, laser-induced RBC volume change was completely abolished by suspending RBCs in a solution containing a higher concentration of EDTA.

Conclusions

It was suggested that LLL can reduce RBC volume possibly because of the increased free intracellular Ca(+2) concentrations, which activate Ca(+2)-dependent K(+) channels with consequent K(+) ion efflux and cell shrinkage.

Resumen reproducido bajo la licencia CC BY. Fuente: PubMed, un servicio de la National Library of Medicine.

Parámetros de luz mencionados

Detectados por patrones en el título y el resumen. Pueden estar incompletos, así que revisa el artículo antes de comparar estudios.

Longitud de onda
405 nm

Cómo leer un estudio individual: qué comprobar antes de fiarte de este tipo de investigación.

Términos de este artículo: Láser. Cada uno enlaza con su definición en el glosario.

Un resumen de investigación publicada, no consejo médico. Un solo estudio rara vez resuelve una cuestión. Consulta el aviso legal y cómo leer la investigación.

Estudios relacionados

Dispositivos y dosimetría

Modulatory Effects of the Er,Cr:YSGG-Diode Laser Combination Irradiation on Human Osteoblasts-Might Be Relevant for Periapical Bone Regeneration?

Ningún protocolo fue citotóxico. El láser de diodo de 810 nm fue la condición más favorable para la osteogénesis, mientras que la irradiación Er,Cr:YSGG de mayor energía suprimió la actividad de la ALP y, cuando se combinó con el diodo, atenuó su efecto osteogénico.

Estudio · 3 de noviembre de 2026 · Ripszky A et al.