Gratis · 13.598 estudios indexados

lighttherapyresearch.com es un índice gratuito de investigación sobre fotobiomodulación y terapia de luz, reunida de las revistas científicas y los registros de ensayos de todo el mundo.

Secciones
Dolor y aparato locomotor

Low-level laser therapy effects on pain perception related to the use of orthodontic elastomeric separators

El uso de una dosis única de LLLT no provocó una reducción significativa de la percepción del dolor ortodóncico. La percepción general del dolor por la colocación de separadores ortodóncicos varió mucho y generalmente fue leve.

Extracto del resumen del artículo, traducido por un modelo de IA. Lee el artículo completo para ver los detalles.

Resumen generado por IA

Los autores estudiaron si una única aplicación de terapia láser de baja intensidad reducía el dolor causado por los separadores elastoméricos ortodóncicos en 79 personas de entre 13 y 34 años, mediante un diseño de boca dividida con grupos de láser, placebo y control. Informan de que no hubo diferencias entre los grupos en las puntuaciones de dolor en ningún momento, y que el dolor en general era normalmente leve.

Participantes
79
Quién o qué se estudió
Personas de entre 13 y 34 años al inicio del tratamiento ortodóncico
Límites indicados en el resumen
El resumen no indica la longitud de onda del láser ni describe el cálculo del tamaño de la muestra, y señala únicamente que se probó una aplicación de dosis única.

Traducido por un modelo de IA a partir del resumen en inglés, que se escribió solo a partir del resumen de este artículo. Las cifras se comprobaron automáticamente con el resumen del artículo, pero el texto aun así puede ser incorrecto. No es consejo médico. Lee el artículo completo. Consulta la política editorial.

Resumen (abstract)

Introduction

Some patients refer to pre-banding orthodontic separation as a painful orthodontic procedure. Low-level laser therapy (LLLT) has been reported to have local analgesic effect.

Objective

The aim of this single-blind study was to investigate the perception of pain caused by orthodontic elastomeric separators with and without a single LLLT application (6J).

Methods

The sample comprised 79 individuals aged between 13 and 34 years old at orthodontic treatment onset. Elastomeric separators were placed in first maxillary molars at mesial and distal surfaces and kept in place for three days. The volunteers scored pain intensity on a visual analogue scale (VAS) after 6 and 12 hours, and after the first, second and third days. One third of patients received laser applications, whereas another third received placebo applications and the remaining ones were controls. Applications were performed in a split-mouth design. Thus, three groups (laser, placebo and control) were assessed.

Results

No differences were found among groups considering pain perception in all periods observed.

Conclusion

The use of a single-dose of LLLT did not cause significant reduction in orthodontic pain perception. Overall pain perception due to orthodontic separator placement varied widely and was usually mild.

Resumen reproducido bajo la licencia CC BY. Fuente: PubMed, un servicio de la National Library of Medicine.

Parámetros de luz mencionados

Detectados por patrones en el título y el resumen. Pueden estar incompletos, así que revisa el artículo antes de comparar estudios.

Energía total
6J

Cómo leer un ensayo clínico: qué comprobar antes de fiarte de este tipo de investigación.

Términos de este artículo: Terapia láser de baja intensidad, Láser, Escala visual analógica, Dosis. Cada uno enlaza con su definición en el glosario.

Un resumen de investigación publicada, no consejo médico. Un solo estudio rara vez resuelve una cuestión. Consulta el aviso legal y cómo leer la investigación.

Estudios relacionados