Radiometric and spectral characterization of multipanel planar light-emitting devices: a generalizable irradiance mapping approach for dose estimation

Este marco permite una caracterización cuantitativa de las propiedades espectrales y radiométricas del dispositivo ATP38®, apoyando un modelado preciso de la propagación de la luz y la optimización de la dosimetría.

Extracto del resumen del artículo, traducido por un modelo de IA. Lee el artículo completo para ver los detalles.

Resumen generado por IA

Los autores describen un método para medir las propiedades espectrales y radiométricas de un dispositivo de fotobiomodulación con múltiples LED (ATP38) y ajustan mapas de irradiancia a superficies gaussianas para estimar la dosis a otras distancias. Se identificaron seis picos de emisión, y las pruebas in vitro en queratinocitos humanos encontraron respuestas biológicas que se correlacionaron con las variaciones espaciales de la irradiancia. Como se trata de una caracterización del dispositivo y de un estudio celular, los hallazgos no establecen efectos clínicos.

Quién o qué se estudió
Queratinocitos epidérmicos humanos normales in vitro; caracterización del dispositivo del sistema ATP38
Longitudes de onda
454, 525, 594, 627, 729, 842 nm
Límites indicados en el resumen
La validación biológica se realizó in vitro en queratinocitos, por lo que el resumen no establece efectos en humanos.

Traducido por un modelo de IA a partir del resumen en inglés, que se escribió solo a partir del resumen de este artículo. Las cifras se comprobaron automáticamente con el resumen del artículo, pero el texto aun así puede ser incorrecto. No es consejo médico. Lee el artículo completo. Consulta la política editorial.

Resumen (abstract)

Significance

Accurate spectral and radiometric characterization of photobiomodulation (PBM) devices is essential for reliable dosimetry and reproducible therapeutic outcomes. Complex, multilight-emitting diode (LED) systems produce heterogeneous irradiance patterns that complicate dose estimation, underscoring the need for standardized quantitative methods.

Aim

To develop and validate a generalizable methodology for the spectral and radiometric characterization of multipanel and multi-LED PBM devices, demonstrated using the ATP38® system. APPROACH: cos m( )θ mSpectral properties were measured using an optical fiber-based spectrometer. The radiometric properties were determined by measuring 2D irradiance maps acquired at a 4-cm working distance from a single panel at six wavelengths. A critical element of the method was correcting raw irradiance data for the detector's nonideal angular response, modeled by afunction, withdetermined for each wavelength. The corrected maps were fitted using double 2D Gaussian surfaces, enabling the generation of continuous irradiance distributions and their extrapolation to other working distances through homothety. This framework also allowed simulation of irradiance maps for multipanel configurations. To validate the physical characterization, in vitro experiments on normal human epidermal keratinocytes compared the biological effects of three illumination protocols applied at two panel locations. PBM effects were assessed by measuring the endogenously produced protoporphyrin IX fluorescence intensity and by the scratch test assay.

Results

Six emission peaks were identified at 454, 525, 594, 627, 729, and 842 nm. The detector angular correction improved the accuracy of the radiometric characterization, and Gaussian modeling of the irradiance enabled its prediction at different working distances. Biological responses correlated with spatial irradiance variations.

Conclusions

This framework enables quantitative characterization of the ATP38® device spectral and radiometric properties, supporting accurate light propagation modeling and dosimetry optimization.

Resumen reproducido bajo la licencia CC BY. Fuente: PubMed, un servicio de la National Library of Medicine.

Parámetros de luz mencionados

Detectados por patrones en el título y el resumen. Pueden estar incompletos, así que revisa el artículo antes de comparar estudios.

Longitud de onda
842 nm

Cómo leer un estudio individual: qué comprobar antes de fiarte de este tipo de investigación.

Términos de este artículo: Irradiancia, Dosis, Fotobiomodulación, Trifosfato de adenosina, Diodo emisor de luz, Dosimetría, Longitud de onda. Cada uno enlaza con su definición en el glosario.

Un resumen de investigación publicada, no consejo médico. Un solo estudio rara vez resuelve una cuestión. Consulta el aviso legal y cómo leer la investigación.

Estudios relacionados

Dispositivos y dosimetría

n-Value-Tuned Quasi-2D Perovskites for Wavelength-Selective Optoelectronic Synapses

Utilizando estas respuestas dependientes de la longitud de onda, la intensidad y la duración, construimos un modelo de regresión del historial de luz que relaciona la exposición acumulada con las advertencias eléctricas de peligro de luz azul y con los umbrales de fototoxicidad derivados de la literatura bajo distintas temperaturas de color.

Estudio · 12 de noviembre de 2026 · Li Y et al.