Résumé (abstract)
Background
Recent studies involving phototherapy applied prior to exercise have demonstrated positive results regarding the attenuation of muscle fatigue and the expression of biochemical markers associated with recovery. However, a number of factors remain unknown, such as the ideal dose and application parameters, mechanisms of action and long-term effects on muscle recovery. The aims of the proposed project are to evaluate the long-term effects of low-level laser therapy on post-exercise musculoskeletal recovery and identify the best dose andapplication power/irradiation time.
Design And Methods
A double-blind, randomized, placebo-controlled clinical trial with be conducted. After fulfilling the eligibility criteria, 28 high-performance athletes will be allocated to four groups of seven volunteers each. In phase 1, the laser power will be 200 mW and different doses will be tested: Group A (2 J), Group B (6 J), Group C (10 J) and Group D (0 J). In phase 2, the best dose obtained in phase 1 will be used with the same distribution of the volunteers, but with different powers: Group A (100 mW), Group B (200 mW), Group C (400 mW) and Group D (0 mW). The isokinetic test will be performed based on maximum voluntary contraction prior to the application of the laser and after the eccentric contraction protocol, which will also be performed using the isokinetic dynamometer. The following variables related to physical performance will be analyzed: peak torque/maximum voluntary contraction, delayed onset muscle soreness (algometer), biochemical markers of muscle damage, inflammation and oxidative stress.
Discussion
Our intention, is to determine optimal laser therapy application parameters capable of slowing down the physiological muscle fatigue process, reducing injuries or micro-injuries in skeletal muscle stemming from physical exertion and accelerating post-exercise muscle recovery. We believe that, unlike drug therapy, LLLT has a biphasic dose-response pattern.
Trial Registration
The protocol for this study is registered with the Protocol Registry System, ClinicalTrials.gov identifier NCT01844271.
Résumé reproduit sous licence CC BY. Source : PubMed, un service de la National Library of Medicine.
Paramètres lumineux mentionnés
Repérés par motif dans le titre et le résumé. Ils peuvent être incomplets : vérifiez l’article avant de comparer des études.
- Longueur d’onde
- 810 nm
- Puissance
- 200 mW, 100 mW, 400 mW, 0 mW
- Énergie totale
- 2 J, 6 J, 10 J, 0 J
Comment lire un essai clinique : ce qu’il faut vérifier avant de se fier à ce type de recherche.
Termes de cet article : Laser, Dose, Thérapie par laser de faible intensité, Contrôlé par placebo, Puissance de sortie, Courbatures d’apparition retardée, Enregistrement d’un essai, Stress oxydatif. Chacun renvoie à sa définition dans le glossaire.
Un résumé de recherches publiées, pas un avis médical. Une seule étude tranche rarement une question. Voir l’avertissement et comment lire la recherche.