A comparison study of 589 and 650 nm on improving stored whole blood stability by irradiation with a low-power diode pumping solid-state laser

Both 589nm and to some extent 650nm low-level laser irradiation generally reduced haemolysis. The wavelength of 589nm lasers had a more effective influence than the 650nm counterpart in improving the stored red blood cells.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors studied whether laser irradiation at 589 nm or 650 nm could improve the stability of stored whole blood in a laboratory setting. Blood samples from healthy adults were stored for 21 days and then exposed to the lasers at several doses. The authors report that 589 nm irradiation was associated with a larger reduction in haemolysis than 650 nm, which they describe as having a smaller effect.

Who or what was studied
Samples of healthy adult human whole blood stored in citrate-phosphate dextrose-adenine tubes, studied in vitro
Wavelengths
589, 650 nm
Limits stated in the abstract
The study was conducted in vitro on stored blood samples, and the abstract does not report the number of samples or donors.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Objective

To assess the effects of diode-pumped solid-state laser irradiation with 589nm and 650nm wavelengths on the stability of stored red blood cells in vitro.

Methods

This is an intervention study that was conducted from April to July 2021 at the Physiology and Medical Physics Laboratory, College of Medicine, Mustansiriyah University, Baghdad, Iraq, and comprised samples of healthy, adult human blood that were put in tubes with citrate-phosphate dextrose-adenine as an anticoagulant. The blood sample was divided into eight equal aliquots and stored for 21 days at 4ºC. The stability test was done on days 0, 7, 14 and 21 of storage time for non-irradiated and radiated aliquots. For 15 minutes, the irradiated aliquots were subjected to a diode-pumped solid-state laser with a wavelength of 589nm or a laser with a wavelength of 650nm at frequencies of 30, 50 and 70 J/cm². Data was analysed using SPSS 24.

Results

Exposure of the whole blood to 589nm and a radiation dose of 70J/cm², 50J/cm² and 30J/cm² was associated with a significant reduction in the percentage of haemolysis that ranged 23-42% throughout the whole storage time. Exposure of the whole blood to 650nm wavelength low-level laser therapy and a radiation dose of 70J/cm², 50J/cm² and 30J/cm² was associated with much less reduction in the percentage of haemolysis that ranged 5-9% throughout the whole storage time.

Conclusions

Both 589nm and to some extent 650nm low-level laser irradiation generally reduced haemolysis. The wavelength of 589nm lasers had a more effective influence than the 650nm counterpart in improving the stored red blood cells.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
650 nm, 589nm, 650nm

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Laser, Fluence, Wavelength, Dose, Low-level laser therapy. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.