Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

Clinical efficacy of semiconductor laser application as an adjunct to conventional scaling and root planing

The higher reduction in tooth mobility and probing depths is probably not predominantly related to bacterial reduction in the periodontal pockets but to the de-epithelization of the periodontal pockets leading to an enhanced connective tissue attachment.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared an 809 nm semiconductor laser applied to periodontal pockets with saline rinsing, both after scaling and root planing, in a split-mouth design. They report that laser-treated teeth showed greater reductions in tooth mobility, pocket depth and clinical attachment loss at 3 months, with no significant differences in plaque, gingival or bleeding measures. The abstract describes the study as in vitro and does not report a control group receiving no treatment beyond saline rinsing.

Participants
22
Who or what was studied
22 healthy patients (15 women, 7 men, mean age 45.0 +/- 10.8 years) with a need for periodontal treatment and at least four teeth in all quadrants
Wavelengths
809 nm
Limits stated in the abstract
The abstract describes the study as in vitro despite involving patients, reports a 3-month follow-up only, and states the mechanism behind the mobility and depth changes is probably not bacterial reduction.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

The full abstract is not shown here because it is protected by the publisher’s copyright. Read it on onlinelibrary.wiley.com.

Record from PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
809 nm

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Laser, Control group, Power output. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies