AI-generated summary
The authors report a randomized controlled trial of 30 adults with deep overbite who had upper incisors intruded using mini-implants, with some receiving low-level laser at 808 nm. Both groups showed significant root shortening and volume loss, but the laser did not significantly change the amount of root resorption compared with controls.
- Participants
- 30
- Who or what was studied
- Adult patients aged about 22 years with deep overbite, 13 males and 17 females, randomized to laser or control groups
- Wavelengths
- 808 nm
- Limits stated in the abstract
- The abstract reports a small sample of 30 patients and does not describe other limitations in detail.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Deep bite is a common characteristic of malocclusion, and many methods are used to treat it, including mini-implants used for the intrusion of the upper incisors. Orthodontically induced inflammatory root resorption (OIIRR) is an inevitable and unexpected side effect of orthodontic therapy. However, resorption of the root could be affected by the type of tooth movement, such as intrusion. Several studies have indicated the effectiveness of low-level laser therapy (LLLT) in accelerating orthodontic movement, but studies that have evaluated the role of this laser in reducing the risk of OIIRR have been limited. This trial aimed to investigate the effectiveness of LLLT in reducing the resorption of the roots of the upper incisors during their intrusion in the context of deep bite correction.
Materials And Methods
Thirty patients (13 males, 17 females; mean age 22.4±3.37 years) with deep overbite were recruited and allocated to the laser or the control groups. Mini-implants were inserted between the roots of the upper central incisors and the lateral incisors from the labial aspect at the gingival-mucosal junction on both sides with a force of 40 g on each side through an NiTi coil spring. A low-level laser (Ga-Al-As) with 808 nm wavelength in a continuous mode, with the parameters 250 milliwatt power output, 4 Joules/point energy density, and 16 seconds irradiation per point, was applied to the root of each of the upper incisors. The laser was applied on the first day of the upper incisor intrusion (T1), then on days 3, 7, and 14 of the first month. In the second month, the laser was applied every 15 days, adjusting the spring strength every four weeks until the end of the intrusion stage (T2), which was determined by reaching a normal overbite. As for patients in the control group, the strength of the nickel-titanium springs was adjusted every four weeks to the required strength of 40 g on each end until reaching a normal overbite.
Results
There was a volumetric decrease in both groups' upper central and lateral incisors roots, and this decrease was statistically significant (P<0.001). However, the difference between the two groups was not statistically significant in each central and lateral incisor volume root (P=0.345 and 0.263 for U1 and U2, respectively). Also, both groups had a linear decrease in upper central and lateral incisors roots, which was statistically significant (P<0.001). At the same time, the difference between the two groups was not statistically significant in each central and lateral incisor root length (P=0.343 and 0.461 for U1 and U2, respectively).
Conclusion
The low-level laser irradiation using the current protocol did not significantly affect the amount of root resorption induced by incisor intrusion in the experimental group compared to the control group.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 808 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Low-level laser therapy, Control group, Power output, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.