The authors measured the power and beam diameter of twenty-four low-power laser photobiomodulation devices in clinical use in Brazil. They report that measured power ranged from 2% to 134% of manufacturer-declared values, and beam diameters differed from nominal values by 38% to 543%, even within the same brand and model. The authors call for better standardization and routine performance monitoring of these devices.
- Who or what was studied
- Twenty-four therapeutic laser devices in clinical use in Brazil, with an average age of 11±5 years and average weekly use under thirty minutes
- Wavelengths
- 830, 904 nm
- Limits stated in the abstract
- The abstract does not describe a patient or clinical outcome measure, so it cannot show effects on treatment results.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Purpose
Daily clinical use of therapeutic light sources can lead to changes in light emission stability with potentially significant consequences for usage in photomedicine treatment. The aim of this study was to evaluate the average and maximum power and to describe the beam diameter of different low-power laser photobiomodulation devices in clinical use in Brazil.
Methods
The power and light-emitting beam diameter of twenty-four therapeutic devices with an average age of 11±5 years, with an average weekly use of fewer than thirty minutes, were measured.
Results
The analyzed power varied between 2% to 134% of the values declared by the manufacturers. Differences in beam diameter of between 38% and 543% of the nominal values were also observed. It is also noteworthy that even between the same brand and model, differences in diameter were obtained. Finally, differences were observed in the power output after one and three minutes of sequential emission for 830 nm and 904 nm (p < 0.05), but not when comparing the difference between wavelengths in factor time.
Conclusion
There is a need for a shared effort on the part of laser manufacturers to improve standardization and consistency of laser output power and beam diameters. At the same time, medical laser operators should also consider development of standardized protocols for maintenance and monitoring equipment performance over time to correct for fluctuations that could ultimately impact on treatment outcomes.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 830 nm, 904 nm
How to read a single study: what to check before relying on this kind of research.